ebooks logo journals logo reference works logo abstract databases logo
bullet  SIGN IN Register | Why Register? | Got a Voucher? alerts   marked lists   shopping cart 
Advert: Informa Healthcare - http://www.informahealthcare.com

informaworld

HOME   |   SEARCH   |   BROWSE
    Issues List       Latest Issue       Forthcoming Articles       Volume 127 Issue 4       Subscribe       Article       References       Related articles      
<< firstfirst   < prevprev   Table of contentstoc   next >next   last >>last
Publisher Logo Publication Cover
Search within this journal

Intraoperative ossicular loading with the Otologics fully implantable hearing device 

Authors: Herman A. Jenkins a;  Nicholas Pergola b; James Kasic b
Affiliations:   a Department of Otolaryngology, University of Colorado, Denver, CO, USA
b Otologics, LLC, Boulder, CO, USA
DOI: 10.1080/00016480601089424
Publication Frequency: 12 issues per year
Published in: journal Acta Oto-Laryngologica, Volume 127, Issue 4 2007 , pages 360 - 364
First Published: 2007
Formats available: HTML (English) : PDF (English)
Article Requests: Order Reprints : Request Permissions


Abstract

Conclusions. Use of the recently introduced intraoperative loading instrumentation during surgery improves the coupling efficiency and consistency of a fully implantable hearing device to the ossicles and ultimately leads to better patient performance with the device. Background. Patient performance with an implantable hearing device is dependent on effective coupling of the implant to the middle ear ossicles. New intraoperative instrumentation aids the surgeon in coupling the implantable hearing device and consistently optimizes patient performance. Materials and methods. The middle ear transfer function for the Otologics MET Ossicular Stimulator (METFMET) is a measure of transducer coupling efficiency, defined as acoustic threshold (in dB HL) minus implant threshold (in dB MET). This transfer function was measured in the Otologics US Phase I Semi-Implantable Clinical Trial without intraoperative loading instrumentation and in the Otologics US Phase I Fully Implantable Clinical Trial with intraoperative loading instrumentation. The same operative techniques and transducer design were used in both studies. The theory of operation and surgical technique for using this instrumentation are described. Results. In the semi-implantable clinical trials, METFMET was -10 to -15 dB for frequencies above 1 kHz, and dropped to -15 to -20 dB for lower frequencies. Fully implantable clinical trial results were 10-20 dB better than the semi-implantable trial results, with less variability at all frequencies. These findings indicate more consistent and better coupling efficiency of the transducer to the ossicles.
Keywords: Loading; ossicles; transducer; Otologics
view references (4)
Bookmark with:
  • CiteULike
  • Del.icio.us
  • BibSonomy
  • Connotea
  • More bookmarks
Privacy Policy | Terms & Conditions | Accessibility | RSS
FAQs in: English . Français . Español . 中文(简体和繁體)
© 2009 Informa plc