ebooks logo journals logo reference works logo abstract databases logo
bullet  SIGN IN Register | Why Register? | Got a Voucher? alerts   marked lists   shopping cart 
Advert: Informa Healthcare - http://www.informahealthcare.com

informaworld

HOME   |   SEARCH   |   BROWSE
    Issues List       Latest Issue       Volume 13 Issue 5       Subscribe       Article       References       Related articles      
<< firstfirst   < prevprev   Table of contentstoc   next >next   last >>last
Publisher Logo Publication Cover
Search within this journal

A New Method for Continuous Chronic Measurement and Recording of Blood Pressure, Heart Rate and Activity in the Rat Via Radio-telemetry 

Authors: Brian P. Brockway ab;  Perry A. Mills ab; Silvia H. Azar ab
Affiliations:   a Data Sciences, Inc., St Paul, MN
b Department of Medicine, University of Minnesota, Mpls, MN
DOI: 10.3109/10641969109042094
Publication Frequency: 8 issues per year
Published in: journal Clinical and Experimental Hypertension, Volume 13, Issue 5 July 1991 , pages 885 - 895
Subject: Hypertension;
Formats available: PDF (English)
Article Requests: Order Reprints : Request Permissions
View Article: View Article (PDF) View Article (PDF)


Abstract

Accurate continuous chronic measurements of blood pressure from conscious laboratory rats are critical to many experimental protocols but have been difficult or impossible to acquire. A system consisting of an implantable radio-telemetry device, receiver, and computer-based data acquisition system that allows such measurements to be easily obtained has been developed. This system is capable of monitoring and recording arterial pressure (waveform, systolic, diastolic, and mean), heart rate, and activity from rats weighing 175 gm for periods in excess of 6 months. Chronic patency has been achieved through a patented design which includes an antithrombogenic film and a get membrane located at the catheter tip. Validation of telemetered measurements via carotid catheter has demonstrated the accuracy to be better than +/- 5 mmHg in 85% (N=20) tested at 3 weeks post implantation, 86% (N=15) tested at 8 weeks, and 78% (N=9) at 12 weeks. Incidence of loss of patency was 2.3% (N=44). This system has a demonstrated ability to obtain accurate continuous chronic measurements of arterial pressure free of the stressors associated with conventional systems.
Keywords: blood pressure; telemetry; heart rate; activity; chronic monitoring
view references (15)
Bookmark with:
  • CiteULike
  • Del.icio.us
  • BibSonomy
  • Connotea
  • More bookmarks
Privacy Policy | Terms & Conditions | Accessibility | RSS
FAQs in: English . Français . Español . 中文(简体和繁體)
© 2009 Informa plc